  1. Barry.Collins

    Plugin fails to load in IIS

    Thanks to fullbrook on Slack for pointing out that a simple iisreset should resolve this. These are the steps I take now to load a plugin; 1) Ensure no scripts are running that can't be killed off safely. 2) Load/Update the plugin. 3) Open a Powershell window and use "Get-Content c:\Program Files)\Labtech\Logs\LTAErrors.txt -wait -last 20". This will give you a live view of the log as it updates. 4) Restart the DB 5) Monitor the log file in the powershell window and wait until it starts setting user permissions (something along the lines of "Perm User Admin:::") 6) Run "iisadmin" in an admin command prompt 7) Check IIS Work Processes to make sure agent check-ins and web requests are coming through and clearing.
  2. Barry.Collins

    Plugin fails to load in IIS

    So this is kind of weird. In our dev environment the plugin will load and run fine however when I try to install it on Live it never seems to get the green check mark under "IIS Loaded". Shortly after all hell breaks loose and we're no longer able to login to Automate. Has anyone else experienced this?
  3. Barry.Collins

    LT11 Patch Manager Incomplete?

    Is it just me or do parts of LT11s Patch Manager just not work? "Patch Job" always states "The selected device does not have any patch job information available" and clicking on a patch item in the dashboard applies a filter for something that doesn't seem to work.. or am I missing something?
  4. Barry.Collins

    Client needs to use their own TightVNC

    Sorry to reopen this but the above solution does not seem to work. LabVNC runs and causes TightVNC to fail.
  5. Barry.Collins

    Powershell Redirector

    That would be a typo. Sorry! It's now fixed.
  6. Barry.Collins

    Slow Tunnels

    I've always had an issue with tunnels in Labtech. They connect just fine with a nice low ping but as soon as any data starts going through the ping goes through the roof and throughput is very slow. Am I missing a configuration somewhere or is this just how it's meant to be? Any redirectors going through it are practically unusable. (I'm on Labtech 10)
  7. Barry.Collins

    Powershell Redirector

    After many hours of frustration I've finally got this to work. This will give you the full Powershell experience as if you'd used Enter-PSSession to access a server in your own LAN. (Requires Tunnels!) Name: Powershell Program: %windir%\system32\WindowsPowershell\v1.0\powershell.exe Arguments: -noexit -command "$cred = get-credential; enter-pssession localhost -port %LocalPort1% -credential $cred" LocalPort: 0 LocalIP: 127.0.0.1 RemotePort: 5985 RemoteIP: %RemoteIP% Socket Function: TCPLocalListen If you have the correct credentials set against the location you can use the following arguments to connect without having to manually enter them each time: -noexit -command "$secpasswd = ConvertTo-SecureString '%computerpassword%' -AsPlainText -Force; $cred = New-Object System.Management.Automation.PSCredential ('%computerdomain%\%computerusername%', $secpasswd); enter-pssession localhost -port %LocalPort1% -credential $cred"
  8. Barry.Collins

    Force Basic on a redirector

    I found the "TunnelBasicBypass" property controls this. Setting this to True enables the behaviour I want. Thanks for your help
  9. Is there a way to force a "Basic" connection (ie not use a tunnel) on a redirector instead of turning off tunnels all together? I've always had speed issues with tunnels and have found that connecting with "Basic" to be much better for RDP and VNC. I know you can [Control]Click the redirector to do this but I'd like this to be default behavior. I managed to do this before in the past at a previous company and now I can't figure it out for the life of me!
  10. Barry.Collins

    Block Shutdown Day of Patching.

    At my old employer I had a script that would run on patch day that created and set a new power profile that had settings that prevented the machine going to sleep due to being idle. A script would then run the next day to remove this profile and set it back to whatever it was set to previously. You could also try a scheduled task that triggers when it detects a shutdown event that runs a simple "shutdown.exe -a" to cancel it. I haven't tested this for when a user actually clicks shutdown, but I know it works when the shutdown command itself is used ("shutdown.exe -s -t 0" for example.)
  11. Barry.Collins

    LT User Policy Plugin

    Would there be a way to use this to deny access to the Ignite tabs as well?
  12. Barry.Collins

    LT User Policy Plugin

    Doesn't seem to work for all plugins. The Connectwise plugin for example. If I set that as disabled it still comes up for the user and if I check the permissions again it is not selected. I have noticed though that the ones it doesn't work for have no, what I guess you can call "internal" name next to the plugin name. I've attached a screenshot.
  13. Barry.Collins

    Server\Workstation Toolpaks

    * Process Explorer http://technet.microsoft.com/en-us/sysinternals/bb896653 * Process Monitor http://technet.microsoft.com/en-us/sysinternals/bb896645 * Treesize http://www.jam-software.com/treesize_free/
  14. Barry.Collins

    LT User Policy Plugin

    This is great. I was looking for something like this only last week. Can't wait for the update
  15. Our technicians do not have administrator privileges on their workstations and so when the recent updates to Control Center started to require this we had a bit of a problem. To get round this we used the Application Compatibility Toolkit to create an application schim that bypasses this. The schim uses the ForceAdminAccess compatibility fix against the LTClient executable. We then created a script to apply the schim and also grant write access to the default Control Center install location. The schim supresses the UAC prompt and the new permissions allow Control Center to load and run correctly. The UAC prompt is being caused by the attempted remapping of LTShare on the global scope. Using this schim will cause this to fail but the user won't be prompted for credentials. We have found that Control Center is still able to access the mapped drive without this and works fine. How To Install • Download attachment and extract • Place Labtech.sdb in your Labtech share under /Transfer/Internal/ • Import script • Run script against target machine Labtech Schim.zip
×